EasyManua.ls Logo

Toshiba E-STUDIO4508A - Page 663

Toshiba E-STUDIO4508A
1016 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
© 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO2008A/2508A/3008A/3508A/4508A/5008A
ERROR CODE AND TROUBLESHOOTING
8 - 125
[EA2D] Paper transport jam in the Finisher (Sub-path sensor)
MJ-1032
[EA2E, EA31] Transport jam in Finisher
Stationary tray full detection
sensor (S11) abnormality
Measure the voltage on TP26 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V±5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Faulty cables and connectors Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connector.
(Finisher control PC board (FIN): CN6, CN10, CN14, CN22)
Finisher control PC board
(FIN) abnormality
If the error still occurs after replacing the sensor and the connector,
replace the finisher control PC board (FIN).
Classification Error content
Paper jam in finisher section Paper transport jam in the Finisher (Sub-path sensor)
Probable cause Checking and measures
2nd transport motor (M4)
abnormality
Check if the electrical continuity of the coil is normal. If electricity is
not conducted, replace the motor.
Entrance path sensor (S19)
abnormality
Measure the voltage on TP86 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Sub-path sensor (S8)
abnormality
Measure the voltage on TP85 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V±5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Stationary tray full detection
sensor (S11) abnormality
Measure the voltage on TP26 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when
not shielded and within the range of 3.3V±5% when shielded. If the
voltage does not fall within the range mentioned, replace the
sensor.
Faulty cables and connectors Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connector.
(Finisher control PC board (FIN): CN6, CN10, CN14, CN22)
Finisher control PC board
(FIN) abnormality
If the error still occurs after replacing the sensor and the connector,
replace the finisher control PC board (FIN).
Classification Error content
Paper jam in finisher section Paper transport remaining jam in the Finisher
Probable cause Checking and measures

Table of Contents

Other manuals for Toshiba E-STUDIO4508A

Related product manuals