SETTING / ADJUSTMENT
4 - 21
4.4.12 Surrounding void amount adjustment
The void amount around the network scanned image is adjusted.
In network scanning, since the void amount is very small in stored images, a shadow may appear
around the scanned image due to the subtle difference in the original sizes. This shadow can be
eliminated by adjusting the setting value.
The setting value is applied to all resolutions and color modes.
<Adjustment Mode (05)>
<Procedure>
The procedure is the same as that of P. 4-15 "4.4.2 Density adjustment".
4.4.13 Judgment threshold adjustment for blank originals (common for
copy and scan)
The judgment level is adjusted for automatic identification of whether the original set is blank or not.
This adjustment is made when “OMIT BLANK PAGE” is selected on the control panel.
The adjustment value is simultaneously applied to all modes at PPC and scanning.
<Adjustment Mode (05)>
<Procedure>
The procedure is the same as that of P. 4-15 "4.4.2 Density adjustment".
4.4.14 JPEG compression level adjustment
The compression level for saving the scanned data in the JPEG format can be adjusted as follows.
<Adjustment Mode (05)>
<Procedure>
The procedure is the same as that of P. 4-15 "4.4.2 Density adjustment".
Code Item to be adjusted Remarks
7489 Surrounding void
amount adjustment
When the value increases, the blank area around the scanned
image becomes wider, and the data on the image decrease.
Acceptable values: 0 to 255 (Default: 0)
The setting value "1" is equal to 1 dot with 600 dpi. (The value
"24" is equal to approx. 1 mm.)
Code Item to be adjusted Remarks
7618 Judgment threshold
adjustment for blank
original
The larger the value is, the more an original tends to be
judged as a bank sheet.
Acceptable values: 0 to 255 (Default: 128)
Code Item to be adjusted Remarks
8304-0 High quality The larger the value is, the better the quality becomes, and
the larger the size of file becomes.
Acceptable values: 0 to 255 (Default: 128)
8304-1 Standard
8304-2 Low quality