Loading...
e-STUDIO477S/527S
05/08
Mode
Element
Sub Element
Item
Subitem
Code
Sub-
Code
Details
Default
value
Acceptable
value
RAM
Contents
Proc
edure
ServiceUI
08
Initialization of department
management information
Initializing of the department management
information
Enter the code with the digital keys and press the
[INITIALIZE] button to perform the initialization.
If the area storing the department management
information is destroyed for some reason, "Enter
Department Code" is displayed on the control
panel even if the department management function
is not set on. In this case, initialize the area with
this code. This area is normally initialized at the
factory.
Setting
mode
System
General
9081
3
SYS
08
Initialization of NIC
information
Returns the value to the factory shipping default
value.
Setting
mode
System
Initialization
9083
3
Yes
SYS
08
Date and time setting
Year/month/date/day/hour/minute/second
Example:
03 07 01 3 13 27 48
"Day" - "0" is for "Sunday". Proceeds Monday
through Saturday from "1" to "6".
Setting
mode
System
General
9100
13 digits
5
-
08
Date display format
0: YYYY.MM.DD
1: DD.MM.YYYY
2: MM.DD.YYYY
<Default value>
MJD: 1
JPD: 0
Others: 2
Setting
mode
System
User interface
9102
Refer to
contents
0~2
1
SYS
08
Time differences
0: +12.0h 1: +11.5h 2: +11.0h 3: +10.5h 4:
+10.0h 5: +9.5h 6: +9.0h 7: +8.5h 8: +8.0h 9:
+7.5h 10: +7.0h 11: +6.5h 12: +6.0h 13: +5.5h
14: +5.0h 15: +4.5h 16: +4.0h 17: +3.5h 18:
+3.0h 19: +2.5h 20: +2.0h 21: +1.5h 22: +1.0h
23: +0.5h 24: 0.0h 25:-0.5h 26: -1.0h 27: -1.5h
28: -2.0h 29: -2.5h 30: -3.0h 31: -3.5h 32: -4.0h
33: -4.5h 34: -5.0h 35: -5.5h 36: -6.0h 37: -6.5h
38: -7.0h 39: -7.5h 40: -8.0h 41: -8.5h 42: -9.0h
43: -9.5h 44: -10.0h 45: -10.5h 46: -11.0h 47: -
11.5h
<Default value>
MJD: 24
NAD: 40
JPD: 6
Others: 0
Setting
mode
System
General
9103
Refer to
contents
0~47
1
SYS
08
Auto-clear timer setting
Timer to return the equipment to the default
settings when the [START] button is not pressed
after the function and the mode are set
0: Not cleared
1 to 10:
Set number x 15 sec.
Setting
mode
System
User interface
9110
3
0~10
1
SYS
54
Ver03
08 Setting Mode

Table of Contents