EasyManua.ls Logo

Toshiba e-Studio477s - Page 225

Toshiba e-Studio477s
482 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2013-2016 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO477S/527S/477SL
REPLACEMENT OF PC BOARDS/HDD
6 - 11
6
3. ID=05 and c5
4. Description of each ID
05 All values are
displayed as “-------”.
High possibility of physical failure (A HDD
connector, harness or SYS board may be one of
the causes.)
HDD
replacement is
recommended.
c5
ID Name Description Remarks
05
Re-allocated Sector
Count
The number of sectors reassigned This value tends
to increase at
HDD failure.
c5
Current Pending
Sector Count
The number of candidate sectors to be
reassigned
This value tends
to increase at
HDD failure.
ID Name Meaning
01
Read Error Rate This attribute is a measure of the read error rate.
02
Throughput Performance This attribute is a measure of the throughput
performance.
03
Spin Up Time This attribute is a measure of how quickly the drive is
able to spin up from a spun down condition.
04
Spin Start/Stop Count This attribute is a measure of the total number of spin
ups from a spun down condition.
05
Re-allocated Sector Count This attribute is a measure of the total number of
reallocated sectors.
07
Seek Error Rate This is a measure of the seek error rate.
08
Seek Time Performance This attribute is a measure of a drive's seek
performance during normal online operations.
09
Power-On Hours This attribute is a measure of the total time (hours or
minutes depending on disk manufacturer) the drive
has been on.
0a
Spin Retry Count This attribute is a measure of the total number of spin
retries.
0c
Power Cycle Count This attribute is a measure of the number of times the
drive has been turned on.
c0
Power off Retract Count This attribute is a measure of the total number of
emergency unloads.
c1
Load Cycle Count This attribute is a measure of the total number of
load/unloads.
c2
Temperature This attribute is a measure of the temperature in the
HDD.
c3
ECC On the Fly Count This attribute is a measure of the total number of the
ECC On the Fly.
c4
Reallocation Event Count This attribute is a measure of the total number of the
reallocation events.
c5
Current Pending Sector Count This attribute is a measure of the total number of
candidate sectors to be reallocated.
c6
Off-Line Scan Uncorrectable
Sector Count
This attribute is a measure of the total number of
uncorrectable sectors found during the off-line scan.
Result