120 RemotEye 4 User Manual 90988-007
MODBUS (3X) INPUT REGISTERS G9000/G2020 PLATFORMS
Registers
Data Type
Description
Units
G9000/G2020
G9000/G2020 V2
Multi
Supp
Multi
Supp
30811
Signed Integer
UPS History Highest Battery Temperature
°C
N/A
N/A
N/A
N/A
30812
Signed Integer
UPS History Highest Battery Temperature
°F
N/A
N/A
N/A
N/A
30813
Unsigned Integer
UPS History Total Number Input Under Voltage
Times
N/A
N/A
N/A
N/A
30814
Unsigned Integer
UPS History Total Number Overloads
Times
N/A
N/A
N/A
N/A
30815
Unsigned Integer
UPS History Total Number Tests
Times
N/A
N/A
N/A
N/A
30816
Unsigned Integer
UPS History Total Number Backup
Times
N/A
N/A
N/A
N/A
30817
Unsigned Integer
UPS History Total Number Faults
Times
N/A
N/A
N/A
N/A
30818
Unsigned Integer
UPS History Total Number Operation Mode Change
Times
N/A
N/A
N/A
N/A
30819
Unsigned Integer
UPS History Total Number Warnings
Times
N/A
N/A
N/A
N/A
30820
Unsigned Integer
UPS History Total Number System Settings Changed
Times
N/A
N/A
N/A
N/A
30821
Unsigned Integer
UPS History Total Number Resets
Times
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
….
N/A
N/A
N/A
N/A
N/A
N/A
N/A
…..
N/A
N/A
N/A
N/A
N/A
N/A
N/A
30850
N/A
N/A
N/A
N/A
N/A
N/A
N/A
UPS Status
30851
Signed Integer
Fan 1 Speed
RPM
N/A
N/A
N/A
N/A
30852
Signed Integer
Fan 2 Speed
RPM
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
….
N/A
N/A
N/A
N/A
N/A
N/A
N/A
…..
N/A
N/A
N/A
N/A
N/A
N/A
N/A
30900
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Note: The Modbus registers table style addressing is protocol base 0. If monitoring software uses PLC style addressing base 1, add one to the register number. For
example, Modbus address 30001 becomes PLC address 30002 ; address 10001 becomes PLC address 10002.
Note 2: Please make sure the latest RemotEye 4 firmware revision is installed in order to use the Modbus register table below. If not, there will be inconsistencies
between RemotEye 4 internal register addressing and this manual. Go to www.toshibaups.com to get the latest RemotEye 4 firmware.
Note 3: There are some parameters that take two Modbus registers to display the correct data, since one register can only go up to 65536 (2^16). Use the following
formula (with example) to calculate the correct value: (Register 1* 0x10000) + Register 2 = Correct Unit Value
e.g. (Register (30276) * 0x10000) + Register (30277) = Correct Value in Watts