9.2.3 Safety system
Total resolution ................................
≤
Number of steps / revolution
≤ 8192
Number of revolutions
..........................
≤ 4096
Accuracy .................................................
256 steps, Single-Turn
SSI interface ................................
Clock± and Data±, twisted in pairs and shielded
Protocol ................................
TR specific with function information and CRC
Min. Hamming distance
4
Clock input ................................
Optocoupler
Clock frequency
.............................
≤ 1 MHz
Output code ................................
Binary
Data output ................................
RS422 (2-wire) according to the EIA standard
Output format
................................
MSB left-justified
Mono time t
M
................................
25 µs ≤ t
≤ 35 µs, typically 30 µs
Cycle time ................................
≥ 500 µs
Counting direction ................................
adjustable by means of hardware switch
9.3 Environmental conditions
DIN EN 60068-2-6 ...........................................
≤ 100 m/s
, sine 50-2000 Hz
DIN EN 60068-2-27 .........................................
≤ 600 m/s
, half-sine 5 ms
Immunity to disturbance ..................................
EN 61000-6-2
Transient emissions ........................................
EN 61000-6-3
Working temperature ..............................................
Tu = f(n) = -20 °C…+70 °C
Double magnetic scanning ..............................
Tu = f(n) = -40 °C…+65 °C
CDV75, for n > 100 1/min, IP54 ......................
Tu = f(n) = 70°C – (0.002 * n)
CDH75, for n > 100 1/min, IP54 ......................
Tu = f(n) = 70°C – (0.005 * n)
Storage temperature ...............................................
-30 °C…+80 °C, dry
Relative air humidity, DIN EN 60068-3-4 ................
98 %, non-condensing
Protection class, DIN EN 60529
1)
..........................
IP 54
1)
valid with screwed-on mating connector and/or screwed-on cable gland