EasyManuals Logo

Triax TDX User Manual

Triax TDX
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
TDX Headend System Main Unit
Black Edition
EN
38
SNMP traps
PowerUp
OID: 1.3.6.1.4.1.41359.1.1.1.1
Trap generated when the TDX will be power cycled.
Login
OID: 1.3.6.1.4.1.41359.1.1.1.2
Trap generated when the web configurator is logged on.
Logout
OID: 1.3.6.1.4.1.41359.1.1.1.3
Trap generated when the web configurator is logged out.
TimeOut
OID: 1.3.6.1.4.1.41359.1.1.1.4
Trap generated when the web configurator is timed out.
FailedLogin
OID: 1.3.6.1.4.1.41359.1.1.1.5
Trap generated when the web configurator login has failed.
Restart
OID: 1.3.6.1.4.1.41359.1.1.1.6
Trap generated when TDX is restarted.
InputError
OID: 1.3.6.1.4.1.41359.1.1.1.7
Trap generated when an input module has an error, e.g. module no longer locked to frequency, missing
module etc,
CIInsertion
OID: 1.3.6.1.4.1.41359.1.1.1.8
Trap generated when a CI module is inserted in the TDX.
CIRemoval
OID 1.3.6.1.4.1.41359.1.1.1.9
Trap generated when a CI module is removed from the TDX.
ModuleInsertion
OID 1.3.6.1.4.1.41359.1.1.1.10
Trap generated when an input or output module is inserted.
ModuleRemoval
OID 1.3.6.1.4.1.41359.1.1.1.11
Trap generated when an input or output module is removed.
CIDescramblingError
OID 1.3.6.1.4.1.41359.1.1.1.12
Trap generated when a service descrambling has an error.
CICommunicationDown
OID 1.3.6.1.4.1.41359.1.1.1.13
Trap generated when communication with CI module fails.
VideoDecodingError
OID 1.3.6.1.4.1.41359.1.1.1.14
Trap generated when video decoding of a service in a PAL output module fails.
InterlinkDisconnect
OID 1.3.6.1.4.1.41359.1.1.1.15
Trap generated when main unit loses connection to a subunit.
ConfigurationChangeApplied
OID 1.3.6.1.4.1.41359.1.1.1.16
Trap generated when the user applies changes in the web configurator.
InputOK
OID 1.3.6.1.4.1.41359.1.1.1.17
Trap generated when an input module error disappears, e.g. errors that can disappear are input module
no longer locked to frequency, missing module etc,
CIDescramblingOK
OID 1.3.6.1.4.1.41359.1.1.1.18
Trap generated when a service descrambling error disappears.
CICommunicationUP
OID 1.3.6.1.4.1.41359.1.1.1.19
Trap generated when communication with the CI module no longer fails.
VideoDecodingOK
OID 1.3.6.1.4.1.41359.1.1.1.20
Trap generated when a video decoding of a service in PAL output module no longer fails.
InterlinkConnect
OID 1.3.6.1.4.1.41359.1.1.1.21
Trap generated when a main unit is connected to a subunit
Manufacturer
Dear Customer
Should you require technical assistance in the event that your expert dealer is unable to help you, please contact us at:
Triax A/S
Bjørnkærvej 3
8783 Hornsyld
Denmark
Tel.: +45 76 82 22 00
mail: triax@triax.dk
web: www.triax.dk

Table of Contents

Other manuals for Triax TDX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Triax TDX and is the answer not in the manual?

Triax TDX Specifications

General IconGeneral
BrandTriax
ModelTDX
CategoryControl Unit
LanguageEnglish

Related product manuals