Model 3440 511
Entering Density Using the Keypad
To enter the density using the keypad, press ¢1² at the Select
Method of Entering Density display. The gauge displays:
Overlay Thickness
#.## in
Input and <ENTER>
Enter the thickness of the overlay (010 in.) and press
¢ENTER/START². The gauge displays:
Bottom Density
#.# pcf
Input and <ENTER>
Enter the wet density of the bottom layer. The gauge enables the
Nomograph function using the entered values, displays a brief
confirmation message, and returns to the Setup menu.
Entering Density Using Gauge Measurements
Bottom density values may be obtained by using the gauge to
record up to 20 actual measurements. To enter the density
using this method, press ¢2² at the Select Method of Entering
Density menu. The gauge displays:
# of Readings to
Average (1-20)?
#
Input and <ENTER>