The gauge displays:
Enter the number of measurements the gauge is to average. Press the
〈ENTER〉 key.
With the source rod in the backscatter position, begin the
measurement by pressing the
〈START〉 key. The gauge displays the
progress.
After taking the reading, the gauge displays the results. To continue,
press the
〈ENTER〉 key. Follow the gauge prompts to complete the
calibration.
Edit a Partial Thin Layer Special Calibration
If a partial calibration was saved earlier, the gauge will display a P
beside the option entered before. Select the value to be completed.
If the value already entered is selected, the gauge prompts the
operator to overwrite. To overwrite the partial calibration, press the
〈YES〉 key and go to page 6–18. To use the stored partial
calibration, press the
〈NO〉 key and select the other value.
To take measurements, see page 6–18. To enter the true density, see
page 6–20.
Lift
Averages
_ _ (3-20)
Then Press ENTER
Count 1 Of xx
Place
in
BS Then
Press
START
6. OFFSETS & CALIBRATIONS