SB80 Work Platform - European 3-5
M
AINTENANCE
Section
3.4
3.4 B
ATTERY
M
AINTENANCE
Battery Inspection and Cleaning
Check battery fluid level daily, especially if work plat-
form is being used in a warm, dry climate. If required,
add distilled water ONLY. Use of tap water will
shorten battery life.
The battery should be inspected regularly for signs of
cracks in the case, electrolyte leakage and corrosion
of the terminals. Inspect cables for worn spots or
breaks in the insulation and for broken cable termi-
nals.
Clean the battery when it shows signs of corrosion at
the terminals or when electrolyte has overflowed dur-
ing charging. Use a baking soda solution to clean the
batteries, taking care not to get the solution inside
the cells. Rinse thoroughly with clean water. Clean
battery and cable contact surfaces to a bright metal
finish whenever a cable is removed
Battery Charging
Charge battery as follows:
1. Check the fluid level. If the electrolyte level is
lower than 10mm (3/8 in.) above the plates, add
clean, distilled water only.
2. Connect the charger plug to a properly grounded
outlet of the proper voltage and frequency.
3. Use a charger which turns off automatically when
the batteries are fully charged.
WARNING
!
!
Hazard of explosive gas mixture. Keep sparks,
flame, and smoking material away from battery.
Always wear safety glasses when working with
batteries.
Battery fluid is highly corrosive. Thoroughly
rinse away any spilled fluid with clean water.
WARNING
!
!
Hazard of explosive gas mixture. Keep sparks,
flame, and smoking material away from battery.
Always wear safety glasses when working with
batteries.
Battery fluid is highly corrosive. Thoroughly
rinse away any spilled fluid with clean water.
WARNING
!
!
Charge the battery only in a well ventilated
area.
Do not charge the battery when the work plat-
form is in an area containing sparks or flames.
Permanent damage will result if the battery is
not immediately recharged after discharging.
Never leave the charger unattended for more
than two days.
Never disconnect the cables from the battery
when the charger is operating.
Keep the charger dry.