Assembly instances implemented by vacon® 100 family vacon • 73
24-hour support +358 (0)201 212 575 • Email: vacon@vacon.com
8
8.3.4 Direction bit in VACON® FBFixedControlWord
If the “RunRev” bit in an Output Assembly has the value 1, and the “RunFwd” bit in the assembly has
the value 0, then the “Direction” bit 1 in the VACON® FBFixedControlWord is set to 1. Otherwise the
bit is set to 0.
8.3.5 Fault Reset bit in VACON® FBFixedControlWord
The “Fault Reset” bit in an Output Assembly is mapped to the “Fault Reset” bit 2 in the VACON®
FBFixedControlWord. Both bits are rising-edge sensitive.
8.3.6 Request Fieldbus Control bit in VACON® FBFixedControlWord
The “NetCtrl” bit in an Output Assembly is not mapped to the “Request Fieldbus Control” bit 8 in the
VACON® FBFixedControlWord because this way you can place the drive to the IO or keypad control
while fieldbus is active.
8.3.7 Request Fieldbus Reference bit in VACON® FBFixedControlWord
The “NetRef” bit in an Output Assembly is not mapped to the “Request Fieldbus Reference” bit 9 in
the VACON® FBFixedControlWord.
8.4 Mapping of VACON® data onto Standard Input Assemblies
This section specifies how the VACON® data is mapped onto the data in the Standard Input
Assemblies.
8.4.1 FBFixedStatusWord
See Chapter 9 "APPENDIX 1 - VENDOR CONTROL AND STATUS WORD DESCRIPTIONS".
8.4.2 Ready Indication bit in VACON® FBFixedStatusWord
The “Ready Indication” bit 0 in the VACON®VACON® FBFixedStatusWord is mapped to the “Ready”
bit in an Input Assembly which supports this bit.
8.4.3 Run/Stop Indication bit in VACON® FBFixedStatusWord
The “Run/Stop Indication” bit 1 in the VACON® FBFixedStatusWord is mapped to the “Running1”
and “Running2” bits in an Input Assembly which supports these bits. The state of the Running1 and