MESSAGE 3, Status Message 
The status message contains the results of the built-in tests. These 
numerical internal monitoring measurement values can be requested with 
the STATUS command. The short status check message, which contains 
a short, clear language report of the system status can be requested with 
command STATUS CHECK. Refer to section FS11 Status Messages on 
page 111. 
Example of status message: 
FSA
FS11 SYSTEM STATUS: OK 
 
Measurement unit: OK 
Receiver: 
 Window cont:      0 backscatter:   35 
 DC saturation:    0 offset:     -0.09 
Transmitter: 
 Window cont:      0 backscatter:    8 
 Intensity:      162 
Contamination compensation:  ON 
Temperatures (unit C): 
 surface: 22.8 CPU: 27.8 RX: 27.3 TX: 29.3 hood RX: 20.3 
 Hood TX: 21.0 
Voltages: 
 +12V: 11.4 -12V:-11.3 VB: 12.5 VR:  6.7 
Heater status: 
 Hood TX:  OFF, hood RX:  OFF, dew:  OFF 
 
Interface unit: OK 
Temperatures (unit C): 
 CPU:  27.1, external: ///// 
Humidity: //// 
Voltages: 
 +12V:   12.1 +12Vout:    0.0 PVin:   23.8 V5I: OFF 
 
Background luminance sensor: OK 
 Window cont:     10 
 Contamination compensation: ON 
 Backscatter:      0 
 CPU: 26.2 hood: 24.6 
 Heater status: hood:  OFF, dew:  OFF 
 V5iso:  ON 
 