EasyManua.ls Logo

Vaisala Indigo300 - Wiring Options; Table 4 Analog Output Terminals; Table 5 Probe Connection Terminals

Vaisala Indigo300
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Terminal Function Notes
24 V - Negative supply voltage
15 … 30 V DC
1)
or 24 V AC ±10 %
50/60 Hz
24 V + Positive supply voltage
1) When used with the HMP7 probe, the minimum required power supply input is 18 V DC.
3.3.1.2 Analog output terminals
Table 4 Analog output terminals
Terminal Function Notes
CH - Analog output channel 1 -
Max. wire size: 1.5 mm
2
(16 AWG), solid
wires or ferrules recommended
CH + Analog output channel 1 +
CH - Analog output channel 2 -
CH + Analog output channel 2 +
CH - Analog output channel 3 -
CH + Analog output channel 3 +
3.3.1.3 Probe connection terminals
The probe connection terminals are delivered pre-wired.
Table 5 Probe connection terminals
Terminal Function Color Notes
24 Vout + Positive supply voltage to
probe
Brown
Max. wire size: 1.5 mm
2
(16 AWG)
RS-485 - RS-485 - White
24 Vout - Power GND and RS-485
common
Blue
RS-485 + RS-485 + Black
3.3.2 Wiring options
Do not energize the power supply before the wiring has been
connected.
CAUTION!
Chapter 3 – Installation
23

Table of Contents

Related product manuals