EasyManua.ls Logo

Vanguard Instruments ATRT-03 - Page 47

Vanguard Instruments ATRT-03
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Model ATRT-03 (v) Operating Instruction
45
Table 15-1. Three-Phase Transformer Test Procedure Steps (cont.)
STEP DESCRIPTION DISPLAY ACTION
13 Select print format
PRINT FORMAT
1.COLUMN
2.DETAILED
Select Column
format print
report
14 Store reading in buffer
KEEP THIS READING?
1.YES
2.NO
Press key 1
15 End test
RUN ANOTHER TEST?
1.YES
2.NO
Press key 2
16 Store Test Results in FLASH EEPROM
SAVE THIS RECORD?
1.YES
2.NO
Press key 1
17 Test Results Saved in FLASH
EEPROM confirmation
RECORD NUMBER 3
HAS BEEN SAVED
Press any Key
18 Return to main menu
1.TEST XFMR 04/12/00
2.SETUP 13:06:02
3.CALCULATOR
4.DIAGNOSTIC
None

Table of Contents