CTC II The steps involved in measuring and testing
Operating Instructions Road measurement
40 © Continental Trading GmbH A2C59512809
6.1.2 Manual Measured Track
1 Press to start the "Manual measuring track" menu.
The CTC II reads the tachograph type.
,
2 Drive up to the start mark.
Stop the vehicle if the pulse changes.
Orient the test track pointer on the start mark of the
measured track.
3 Start the measurement procedure.
Drive at a steady walking speed along the measured track.
4 After passing the end marker (if the pulse changes), stop the
vehicle and the measurement procedure.
5 Use a measuring tape to measure the track.
6 Enter the measured track length and confirm.
7 Press to adjust the K value to match the determined W value.
The CTC II programs the determined W value in the
tachograph.
Remark:
The K value may deviate by ± 2 imp/km from the determined
W value, due to electronic splitting.
8 End the program.
If the determined characteristic coefficient "W" deviates by
±1% from the set device constant, the K value must be
adjusted accordingly.
Important

Table of Contents