Error messages
CTC II error messages
12.3.2 Road measurement
12.3.3 Tachograph communication
Error message Cause/ Measure to correct error
1
Too many pulses were counted during manual
measurement, evaluation is not possible.
Measures:
Check diagnostic cable.
Possibly shorten the measured track.
2
Too few pulses were counted during manual
measurement, evaluation is not possible.
Measures:
Check diagnostic cable and replace if necessary.
Possibly lengthen the measured track.
! ERROR !
TOO MUCH PULSES
CONTINUE WITH KEY
! ERROR !
NOT ENOUGH PULSES
CONTINUE WITH KEY
Error message Cause/ Measure to correct error
1
The CTC II cannot read a connected tachograph.
Measures:
Check diagnostic cable and replace if necessary.
Check connections.
2
The CTC II cannot establish a connection with the
Roller Interface Module.
Measures:
Check Bluetooth communication.
Check connections.
Check Roller Interface Module power supply.
3
Communication error on the data interface to DTCO
or to computer.
Measures:
Check diagnostic cable.
Check serial connection to computer.
Check connections.
! ERROR !
TCO – COMM. TIMEOUT
CONTINUE WITH KEY
! NO CONNECTION !
KITAS <
PROGRAMMING
CHECKSUM/TEST
! ERROR !
TCO - COMM. ERROR
CONTINUE WITH KEY