CTC II Error messages
Operating Instructions CTC II error messages
82 © Continental Trading GmbH A2C59512809
12.3.5 Other error messages
Error message Cause/ Measure to correct error
1
The current test program cannot be carried out with
the connected tachograph.
2
No clock calibration has been carried out for the
CTC II. No test can be carried out.
Measures:
– Send the device (via your VDO service partner) to
Continental Trading.
3
No data is available for transfer from the CTC II to
the tachograph.
The saved data does not match the current type of
tachograph.
Measures:
– Read the tachograph data.
– Check tachograph functions.
4
Not enough years to load the change-over times into
the tachograph.
Measures:
– Edit the change-over times table manually.
– Your VDO service partner will load a new table of
change-over times for you.
5
Flash memory programming error.
Measures:
– Send the CTC II to your VDO service partner for
repair.
6
CTC II device hardware defective.
Measures:
– Send the CTC II to your VDO service partner for
repair.
! ERROR !
TCO NOT SUPPORTED
CONTINUE WITH KEY
! ERROR !
CLOCK NOT CALIBRATED
CONTINUE WITH KEY
! ERROR !
NO DATA AVAILABLE
CONTINUE WITH KEY
! ERROR !
NOT ENOUGH YEARS
CONTINUE WITH KEY
! ERROR !
FLASH PROGRAMMING
CONTINUE WITH KEY
! ERROR !
FLASH ERASURE
CONTINUE WITH KEY