CTC II Technical data
Operating Instructions Technical data - Roller Interface Module
88 © Continental Trading GmbH A2C59512809
14.2 Technical data - Roller Interface Module
Measured track for
road measurement
20 m
Test speed for "W"
and "L"
measurements on the
road
manual 0 ... 15 km/h, automatic 3 ... 25 km/h
Power supply 100 … 240V AC ± 10 %, 50Hz, 60Hz
Overvoltage category II
Current consumption max. 1A
Device fuse 1A slow triptime
Operating temperature 0 ... +40 °C
Storage temperature -20 ... +70 °C
Humidity max. 80 %, non-condensing
Type of protection IP54
Contamination level II
Dimensions 200 x 180 x 95 mm
Weight 1.5 kg
Switching output for lifting bar/
brakes
Alternating contact, supply voltage, contact load
0.6A, fused via device fuse
Connections Voltage output for sensor supply:
12V DC ± 15%, 1A short-circuit-proof
Roller sensor (NPN or push-pull):
0.2 … 5 cm/imp
Light barrier for wheel circumference
measurement (NPN or push-pull)
Correction value setting ± 9.9 % in increments of 0.1 %