Tachograph programming
TCO parameters
Dim parameters Brightness of device
illumination when light off
or on.
Light off:
DTCO 1381:
0 - 100, 0 – 250 (CAN)
SE5000: 0 – 255
Light on:
DTCO 1381: 0 – 100
SE5000: 0 – 255
Dimm-mode preset Selection of the dimming
parameter record.
DTCO 1381 Rel. 1.3: 0 – 4
Military dimming Military mode. DTCO 1381 Rel. 1.3: on/ off
Preferred language Default language setting
if available for the TCO.
SE5000, SmarTach
®
:
22 languages
Adopt card language Setting whether or not
the language of the
inserted card or the
default language should
be used.
SmarTach
®
: yes/ no
Addit. input D1/D2 Additional inputs can be
enabled/ disabled if the
TCO hardware supports
this function.
DTCO1381: on/ off
Activity ignition
Driver 1 or 2
For igniton on/ off and for
driver 1 or 2 you can
program whether or not
the DTCO is to switch to
time group setting
automatically.
DTCO Rel. 1.2a/ 1.2U:
break/ rest
availability
•work time
no change (of time group)
Self-control The DTCO's auto-
monitoring level can be
programmed.
DTCO Rel. 1.2a/ 1.2U:
Level 1 should always be
programmed to ensure that the
DTCO works properly.
Program Remark Value/ Information