VTK‐VS‐BA‐004e‐B|UserManualMDS3200A | Communication Interfaces
41
Return: 2
Thenozzleiscorrectlyadjusted.Theadjustwassuccessful.
4. ADJUST:START
Description: Sendingthisinstructioncausestheadjusttobeexecutedatonce.This
procedure,requiredduringeachinitialstart‐upandafterreplacingthe
nozzleunit,decidesonthepositionofthenozzleinsertwithrespectto
thetappet.Theresulthastobeverifiedbythepreviouslydescribed
commandno.3.
Example:
Input: ADJUST:START
Result: Theadjustisinitiated.
Return: OK
5. HEATER:1:OFF
Description: TheheaterconnectedtothesocketisswitchedOFF.
Example:
Input: HEATER:1:OFF
Result: Thenozzleheaterisdeactivated.
Return: OK
6. HEATER:1:ON
Description: Theheaterconnectedtothesocketisturnedon.Itisimportanttoknow
thatthisactionhasaninfluenceonthedelayselectedinthecurrent
parameterconfiguration.Ifavalue<4.6mshasbeenentered,itwill
automaticallybeincreasedtothislimit.
Example:
Input: HEATER:1:ON
Result: Thenozzleheaterisactivated.
Return: OK
7. KEY:ENTER
Description: Theacknowledgementsignalistransferredtothecontrolunit.
Thefunctioniscompletelyidenticaltopressingthe[enter]keyon
thekeypad.
Example:
Input: KEY:ENTER
Result: AnENTERsignalissent.
Return: OK(nofurtherreaction)
8. KEY:ESCAPE
Description: Likebypressingthe[esc]key,thisinstructionabortsthecurrentpro‐
grammingstepwithoutsaving.
Example:
Input: KEY:ESCAPE
Result: TheEscapesignalistransmitted.
Return: OK(nofurtherreaction)