VTK‐VS‐BA‐004e‐B|UserManualMDS3200A | Communication Interfaces
42
9. LCD?
Description: Thiscommandisusefultoinspectexternallythecurrentcontentof
thescreen.
Example:
Input: LCD?
Result: Whensendingthiscommandimmediatelyafterswitching
ON,thecontentofthescreenwillbe“READYMaint.“
Return: (inthiscase)“ReadyMaint.“
10. SYSTEM:KLOCK:OFF
Description: Accesstokeypadispermitted,thelockingfunctiondisabled.
Example:
Input: SYSTEM:KLOCK:OFF
Result: Thekeypadofthecontrolunitcanbeusedfromnow
on.
Return: OK
11. SYSTEM:KLOCK:ON
Description: Thisinstructionlocksthekeypadofthecontrolunit.Thiswayun‐
authorizedmodificationofparameterscanbeprevented.
Example:
Input: SYSTEM:KLOCK:ON
Result: Thekeypadislocked.
Return: OK
12. TEMP:?
Description: Theuserisinformedaboutthecurrent(real)temperatureofthenozzle
heater;themeasuringunitis°C.
Example:
Input: TEMP:?
Result: 70
…thecurrenttemperaturevalueamountsto70°C.
Return: 70
13. TEMP:<Setpointin°C>
Description: Thiscommandisusedtoselectanewtargetvaluefortheheater;the
measuringunitis°C.
Example:
Input: TEMP:60
Result: Fromnowon,thetemperaturecontrolsetstheheating
temperatureto60°C.
Return: OK
14. MAINT:STATUS