Chapter 5: Detailed description of parameters
185
Specifies setting parameters of the channel 0. You can make convenient switching
between setting channels. When multiple-command or simple PLCs are used as the source
of frequency, switching between two frequency sources can be easily implemented.
Group PD: Communication parameters
See the special appendix "Communication protocol V 800 and directories"
Group PP: Restoring the factory setting and blocking the change of
parameters
PP.00
User Password
Default
0
Setting range
0 - 65535
If the parameter is set to any nonzero number, password protection is enabled. After
setting up and executing a password, enter the correct password to enter the menu. If the
entered password is incorrect, you cannot view or modify the parameters. If PP.00 is set to
00000, the previously set user password is cleared and password protection is off.
PP.01
Restore factory settings
Default
0
Setting range
00
No activity
01
Restore factory setting except motor
parameters
02
Delete records
11
High frequency controll
1: Restore factory setting except motor parameters
If PP-01 is set to 1, most of the function codes are reset to the default setting, except for
motor parameters, (P0.22) frequency range setting, fault logs, total running time (P7.09),
total switch-on time (P7.13 ) and total energy consumption (P7.14).
2: Delete records
If PP.01 is set to 2, fault records, total run time (P7.09), total switch-on time (P7.13), and
total power consumption (P7.14) are deleted.
11: High frequency control activated If you want to manage e.g. high frequency spindle
(generally above 100 Hz) activate this parameter
PP.04
Blocking of parameter changes
Default
0
Setting range
0: Parameter change allowed
1: Parameter change is blocked