Chapter 4: List of function parameters - shorted
84
PA.27
Detection time when
PID controller
feedback is lost
0.0s - 20.0s
0.0s
PA.28
Behaviour of PID in
case of loss of
feedback
0: No action of PID and STOP
1: PID action and STOP
0
Group Pb: Variable frequency, fixed length and count
Function
code
Parameter name
Setting range
Default
setting
Attribute
Pb.00
Set the swing
frequency mode
0: Relative to the mean value of the
frequency
1: Relative to the maximum value of the
frequency
0
Pb.01
Amplitude of swing
frequency
0.0% - 100.0%
0.0%
Pb.02
Amplitude of the
jump frequency
0.0% - 50.0%
0.0%
Pb.03
Frequency swing
cycle
0.1s - 3000.0s
10.0s
Pb.04
Time coefficient of
triangle wave rise
0.1 % - 100.0%
50.0%
Pb.05
Set length
0m - 65535m
1000m
Pb.06
Actual length
0m - 65535m
0m
Pb.07
Number of pulses
per meter
0.1 - 6553.5
100.0
Pb.08
Set counter value
1 - 65535
1000
Pb.09
Determined counter
value
1 - 65535
1000