Chapter 4: List of function parameters - shorted
81
Function
code
Parameter name
Setting range
Default
setting
Attribute
P9.62
Voltage during
power failure
60.0 % - 100.0 % (bus voltage)
80.0%
P9.63
Protection at zero
load
0: disabled
1: enabled
0
P9.64
Level of zero load
detection
0.0-100.0%
10.0%
P9.65
The zero load
detection time
0.0-60.0s
1.0s
P9.67
Reserved
P9.68
Reserved
P9.69
Reserved
P9.70
Reserved
Group PA: PID process control functions
Function
code
Parameter name
Setting range
Default
setting
Attribute
PA.00
Setting of source the
required value of PID
0: PA.01
1: FIV
2: FIC
3: Reserved
4: IMPULSE setting (S3), option
5: Communication setting
6: Multiple meaning
0
PA.01
Digital setting of PID
0.0% - 100.0%
50.0%
PA.02
Setting of source the
feedback of PID
0: FIV
1: FIC
2: Reserved
3: FIV-FIC
4: IMPULSE setting (S3), option
5: Communication setting
6: FIV+FIC MULTI REFERENCE
7: MAX(|FIV|, |FIC|)
8: MIN(|FIV|, |FIC|)
0