Chapter 4: List of function parameters - shorted
72
Group P8: Auxiliary functions
Function
code
Parameter name
Setting range
Default
setting
Attribute
P8.00
Jog (JOG) frequency
0.00 Hz – maximum frequency
2.00Hz
☆
P8.01
Jog acceleration
(JOG)
0.0s - 6500.0s
20.0s
☆
P8.02
Jog deceleration
(JOG)
0.0s - 6500.0s
20.0s
☆
P8.03
Acceleration time 2
0.0s - 6500.0s
by the
model
☆
P8.04
Deceleration time 2
0.0s - 6500.0s
by the
model
☆
P8.05
Acceleration time 3
0.0s - 6500.0s
by the
model
☆
P8.06
Deceleration time 3
0.0s - 6500.0s
by the
model
☆
P8.07
Acceleration time 4
0.0s - 6500.0s
by the
model
☆
P8.08
Deceleration time 4
0.0s - 6500.0s
by the
model
☆
P8.09
Jump frequency 1
0.00Hz – maximum frequency
0.00Hz
☆
P8.10
Jump frequency 2
0.00Hz – maximum frequency
0.00 Hz
☆
P8.11
Amplitude of the
jump frequency
0.00Hz – maximum frequency
0.01Hz
☆
P8.12
Dead zone time
when changing
rotation
0.0s - 3000.0s
0.0s
☆
P8.13
Control of reverse
run
0: disabled
1: enabled
0
☆
P8.14
Mode of operation
when the set
frequency is lower
than the lower limit
0: RUN at the lower frequency limit
1: Stop
2: RUN at zero speed
0
☆
P8.15
Balance control
0.00Hz - 10.00Hz
0.00Hz
☆
P8.16
Limit of total turn-on
time
0h – 65000 hours
Oh
☆
P8.17
Total time of
operation the inverter
0h – 65000 hours
Oh
☆
P8.18
The protection at
start
0: disabled
1: enabled
0
☆