Chapter 4: List of function parameters - shorted
90
Group PP: Restoring the factory settings and blocking
the change of parameters
Function
code
Parameter name
Setting range
Default
setting
Attribute
PP.00
User Password
0 - 65535
0
PP.01
Restore factory
settings
0: No activity
01: Restore factory setting except motor
parameters
02: Delete records
11: High frequency control activated
0
PP.04
Blocking of
parameter changes
0: Parameter change allowed
1: Parameter change is blocked
Group C0: Torque control and parameter limitation
C0.00
Selection of control
the speed / torque
0: Speed control
1: Torque control
0
C0.01
Torque control source
settings
0: Digital setting (C0.03)
1: FIV
2: FIC
3: Reserved
4: IMPULSE setting, option
5: Communication setting
6: MIN (FIV,FIC )
7: MAX (FIV,FIC )
0
C0.03
Digital setting of
torque control
-200.0% - 200.0%
150.0%
C0.05
Maximum frequency
forward at torque
control
0.0 Hz maximum frequency
50.00Hz
C0.06
Maximum frequency
backward at torque
control
0.0 Hz maximum frequency
50.00Hz
C0.07
The acceleration time
for torque control
0.00s - 650.00s
0.00s
C0.08
The deceleration time
for torque control
0.00s - 650.00s
0.00s
Groups C1-C4: Reserved

Table of Contents