Chapter 4: List of function parameters - shorted
83
Function
code
Parameter name
Setting range
Default
setting
Attribute
PA.17
Derivation constant
Td2
0.000s - 10.000s
0.000s
PA.18
Switching condition of
PID parameters
0: No switching
1: Switching over S
2: Automatic switching based on
deviation
0
PA.19
Parameter switching
deviation PID 1
0.0% - PA.20
20.0%
PA.20
Parameter switching
deviation PID 2
PA.19 - 100.0%
80.0%
PA.21
Initial value of PID
0.0% - 100.0%
0.0%
PA.22
Initial value of
delaying PID
0.00-650.00s
0.00s
PA.23
Maximum deviation
between two PID
outputs in the
forward direction
0.00% - 100.00%
1.00%
PA.24
Maximum deviation
between two PID
outputs in the
backward direction
0.00%-100.00%
1.00%
PA.25
Properties of PID
integration
.X: Separated integration
0: disabled
1: enabled
X.: Stop the integration when the output
reaches the required limit
0: Continuing of integration
1: Stop of integration
00
PA.26
Detection of PID
controller feedback
loss
0.0%= loss of feedback is not detected
0.1%: 100.0%
0.0%