Chapter 4: List of function parameters - shorted
76
Function
code
Parameter name
Setting range
Default
setting
Attribute
P9.07
To test short to
ground after
switching on
1: test
0: do not test
1
P9.09
Auto restoration
times after
malfunction
0 - 20
0
P9.10
Output state M01
during auto-recovery
after malfunction
0: no activity;
1: activity
0
P9.11
Auto-recovery
interval after
malfunction
0.1s-100.0s
1.0 s
P9.12
Reserved
P9.13
Turn on protection
when the output
phase fails
0: disabled
1: enabled
1
P9.14
The first type of
malfunction
0: No fault
1: Inverter fault
2: Over current during acceleration
3: Over current during deceleration
4: Over current at constant speed
5: Overvoltage during acceleration
6: Overvoltage during deceleration
7: Overvoltage at constant speed
8: Braking resistance overload
9: Low Voltage
10: Overloaded inverter
11: Overloaded motor
12: Reserved
13: Power phase failure
14: Overheating of the inverter
15: External device error
16: Communication error
17: Contactor Error
18: Error of current detection
19: Error of automatic tuning
20: Reserved
21: EPROM memory error
22: Hardware error of the inverter
-

Table of Contents