5-38 BA 357-00 * 3.0 * 35700_05_Bedienung.fm
5 Operation
Important information on connecting and operating the hydraulic control circuits
Connecting the flexible lines incorrectly results in malfunctions and/
or uncontrolled movements of the attachment!
Failure to observe this can cause serious injury or death.
► Ensure that the flexible lines of the attachment are correctly connected
to the machine.
► Follow the instructions in the Operator’s Manual
of the attachment manufacturer.
► Check the response direction of the control
elements before using the attachment.
Risk of injury due to pressure!
A fine jet of hydraulic oil under high pressure
can penetrate through the skin.
► Seek medical attention immediately if hydraulic oil penetrates the skin
or eyes.
► Only open sections of the hydraulic system after the pressure in them
has been released.
► Wear protective clothes.
In order to avoid damage, do not connect the hydraulic lines crosswise,
otherwise the attachment functions are inverted and the hydraulic lines
are squeezed by tilting the attachment in and out.
► Check the attachment for correct function after connecting.
In order to avoid leaks on the plug coupling:
► carefully clean the plug couplings and flexible
lines before connecting them.
► Before connecting the flexible lines, release the pressure from the lines
– see "Pressure relief – plug couplings" on page 5-33.
► When removing an attachment, always ensure that all hydraulic lines
are removed.