BA 357-00 * 3.0 * 35700_05_Bedienung.fm 5-69
Operation 5
Hose burst valve (partly opt)
The hose burst valve prevents the loader unit from being lowered or tilted
out without being braked, in the event of a bursting hose or pipe!
The lift or tilt cylinders are locked and can no longer be operated.
– see "Hose burst valve (partly opt)" on page 5-102
Operating time of battery
The battery can be damaged both by charging it too frequently as well as
by charging new batteries it too late (deep discharge)!
► Observe the notes on charging batteries on page 4-46.
► Recharge the battery in timely fashion. Pay attention to the
“Battery charge condition” indication.
The operating time of the battery depends on the operating conditions, the
application and on how machine travel is performed.
Operating conditions
Battery
416 Ah (AGM)
Heavy jobs min. 3 h
Light jobs min. 5 h