7-26 BA 357-00 * 3.0 * 35700_07_Wartung.fm
7 Maintenance
WARNING
Risk of explosion from static charging!
Cleaning with a feather duster or dry cloths made of synthetic fibers can
lead to static charging and thus to a gas explosion.
Serious injuries and death can result.
Only clean the battery surfaces with cotton or paper towels moistened
with water.
NOTICE
It is possible to clean the battery with a high-pressure cleaner. Cleaning
with a high-pressure cleaner can damage the battery's plastic parts, cell
lids, cell connector insulation or cell plugs. The following must be
observed if the battery is cleaned with a high-pressure cleaner:
Before cleaning, check whether the cell connectors
are firmly tightened and inserted.
Before cleaning, check whether the cell plugs are shut.
Maintain a distance of at least 30 cm (12 in) between
the nozzle and the battery.
Do not exceed an operating pressure of 50 bar (725 psi).
Only spray broadly across the battery.
Do not continue to spray on any single location
for more than 3 seconds.
NOTICE
Cleaning can damage the battery!
Only clean the battery with water.
Do not use any cleaning additives.
Do not exceed a maximum cleaning temperature of 60 °C (140 °).
Dry the battery surface after cleaning with appropriate means.