BA 357-00 * 3.0 * 35700_07_Wartung.fm 7-57
Maintenance 7
1. Park the machine on level ground.
2. Retract all hydraulic cylinders.
3. Apply the parking brake.
4. Turn the machine off and remove the ignition key.
5. Clean the area around breather filter B.
6. Place a container under the hydraulic oil reservoir to collect the oil.
7. Open breather filter B by hand.
8. Add hydraulic oil with the filter insert in place.
9. Check the hydraulic oil level in sight glass A.
- If the oil level is visible in the lower half of the oil level sight glass: oil
level is OK.
10.Add if necessary and check again.
11.Firmly close breather filter B by hand.
Information
Excess hydraulic oil is released via the breather filter during loader unit
operation.
Drain the oil into a suitable collecting container until the oil level can be
seen in the oil level glass A.