Hydraulic system – checking membrane accumulators
Important safety instructions for checking the membrane
accumulators
WARNING
Risk of suffocation through uncontrolled release of large quantities
of gas and risk of injury due to entrained components.
Failure to observe this can cause serious injury or death.
Immediately put machine out of operation in case of leaking or
damaged membrane accumulators.
Never search for leaks with your bare hands.
Have the membrane accumulator checked only by an authorized
service center in accordance with the maintenance plan intervals.
Never weld or solder defective or leaky membrane accumulators.
Damaged membrane accumulators cannot be repaired and must be
replaced by an authorized service center.
WARNING
Danger of explosions by filling the membrane accumulator
with non-permitted gas!
Failure to observe this can cause serious injury or death.
Have work on the membrane accumulator performed
only by an authorized service center.
Information
Maintenance intervals see "Maintenance plan" on page 7-6.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson KRAMER 5055e and is the answer not in the manual?

Wacker Neuson KRAMER 5055e Specifications

General IconGeneral
BrandWacker Neuson
ModelKRAMER 5055e
CategoryFront End Loaders
LanguageEnglish

Related product manuals