BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm 8-9
Malfunctions 8
Main controls (continuation)
Error code FMI
Warning
light
Error description Remedy
518420
9 Yellow
N004 – MLS Interface A/B (I/O controller):
Missing signal
– Both electric engines go via ramp
into emergency shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
11 Yellow
N004 – MLS Interface A/B (I/O controller):
Error description not identifiable
– Both electric engines go via ramp
into emergency shutdown
12 Yellow
N004 – MLS Interface A/B (I/O controller):
Control error (controller)
– Both electric engines go via ramp
into emergency shutdown
19 Yellow
N004 – MLS Interface A/B (I/O controller):
Missing communication between components
– Both electric engines go via ramp
into emergency shutdown
518421 12 Yellow
N004 – MLS Interface A/B (I/O controller):
Control error (controller)
– Both electric engines immediately go
into emergency shutdown
518430
9 Yellow
N004 MLS Drive 1 (operating engine controller):
Missing signal
– Operating engine immediately goes
into emergency shutdown
11 Yellow
N004 – MLS Drive 1 (hydraulic engine controller):
Error description not identifiable
– Operating engine immediately goes
into emergency shutdown
12 Yellow
N004 MLS Drive 1 (hydraulic engine controller):
Control error (controller)
– Operating engine immediately
goes into emergency shutdown
19 Yellow
N004 MLS Drive 1 (hydraulic engine controller):
Missing communication between components
– Machine immediately goes into emergency
shutdown