8-10 BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
Main controls (continuation)
Error code FMI
Warning
light
Error description Remedy
518440
9 Yellow
N004 – MLS Drive 2 (controller):
Missing signal
– Both electric engines go via ramp into
emergency shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
11
Red
N004 – MLS Drive 2 (hydraulic engine controller):
Error description not identifiable
– Operating engine immediately goes into
emergency shutdown
Critical error
1. Repeat startup process.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
12
Red
N004 – MLS Drive 2 (operating engine controller):
Control error (controller)
– Machine immediately goes into emergency
shutdown
19 Yellow
N004 – MLS Drive 2 (operating engine controller):
Missing communication between components
– Both electric engines go via ramp into
emergency shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.