BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm 8-11
Malfunctions 8
Main controls (continuation)
Error code FMI
Warning
light
Error description Remedy
518450
9 Yellow
N004 – MLS Safe A/B (safety controller):
Missing signal
– Both electric engines go via ramp into
emergency shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
11
Red
N004 – MLS Safe A/B (safety controller):
Error description not identifiable
– Machine goes into emergency shutdown
Critical error
1. Repeat startup process.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
12
Red
N004 – MLS Safe A/B (safety controller):
control error (controller)
– Machine goes into emergency shutdown
– Machine able to travel with reduced output
19 Yellow
N004 – MLS Safe A/B (safety controller):
Missing communication between components
– Both electric engines go via ramp into
emergency shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
518451 12
Red
N004 – MLS Safe A/B (safety controller):
control error (controller)
– Machine goes into emergency shutdown
Critical error
1. Unlock motor isolating
switch.
2. Repeat startup process.
3. If the error occurs again:
have the error corrected by
an authorized service
center.

Table of Contents