8-12 BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
Main controls (continuation)
Error code FMI
Warning
light
Error description Remedy
518460
9 Yellow
N004 – ICE_PIO (controller StVZO module):
Missing signal
– Both electric motors go via ramp into emergency
shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
11 Yellow
N004 – ICE_PIO (controller StVZO module):
Error description not identifiable
– Both electric motors go via ramp into emergency
shutdown
12 Yellow
N004 – ICE_PIO (controller StVZO module):
Control error (controller)
– Both electric motors go via ramp into emergency
shutdown
19 Yellow
N004 – ICE_PIO (controller StVZO module):
Missing communication between components
– Both electric motors go via ramp into emergency
shutdown