8-16 BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
Steering system
Error code FMI
Warn-
ing
light
Error description Remedy
518971
3
Yellow
S022 – Switch (steering mode changeover):
Signal range exceeded or short circuit to positive
supply voltage
– only all-wheel drive possible
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
26 Yellow
S022 – Switch (steering mode changeover):
Signal outside of the valid range
– only all-wheel drive possible
27 Yellow
S022 – Switch (steering mode changeover):
Open circuit or short circuit to ground
– only all-wheel drive possible
519355
5 Yellow
Y006 – Magnetic valve (front axle steering):
Power too low or open wiring
– only all-wheel drive possible
6 Yellow
Y006 – Magnetic valve (front axle steering):
Power too high or short circuit against vehicle
ground
– only all-wheel drive possible
519356
5 Yellow
Y007 – Magnetic valve (all-wheel drive):
Power too low or open wiring
– only front axle steering possible
6 Yellow
Y007 – Magnetic valve (all-wheel drive):
Power too high or short circuit to vehicle ground
– only front axle steering possible