EasyManua.ls Logo

Wacker Neuson KRAMER 5055e

Wacker Neuson KRAMER 5055e
420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm 8-17
Malfunctions 8
Hydraulic motor
Error code FMI
Warning
light
Error description Remedy
518431 12
Red
N004: Control error (controller)
– Machine immediately goes into emergency
shutdown
Critical error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
518432
0Yellow
N004 – Threshold exceeded by far
– Machine immediately goes into emergency
shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
1Yellow
N004 – Threshold exceeded by far
– Machine immediately goes into emergency
shutdown
12 Yellow
N004: Control error (controller)
– Temperature on the heat sinks is faulty
– Machine can continue to be operated without
loss of output. The output loss is
temperature-dependent and
occurs in three stages.
If the temperature is not lowered:
– Machine immediately goes into emergency
shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
Critical error
Have the error rectified by an
authorized service center.
16 Yellow
N004 – Threshold exceeded
– Vehicle can still be operated in emergency
operation
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
18 Yellow
N004 – Slightly below threshold
– Vehicle can still be operated in emergency
operation

Table of Contents

Related product manuals