8-18 BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
Hydraulic engine (continuation)
Error code FMI
Warning
light
Error description Remedy
518433
0 Yellow
N004 – Threshold exceeded by far
– Machine immediately goes into emergency
shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
12 Yellow
N004: Control error (controller)
– Temperature on the heat sinks is faulty
– Machine can continue to be operated with loss
of output. The output loss is
temperature-dependent and occurs in three
stages.
If the temperature is not lowered:
– Machine immediately goes into emergency
shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
Critical error
Have the error rectified by an
authorized service center.
16 Yellow
N004 – Threshold exceeded
– Vehicle can still be operated in
emergency operation
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
518434 0 Yellow
N004 – Threshold exceeded by far
– Machine immediately goes into emergency
shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
518436 2 Yellow
N004 – Signal faulty or irregular
– Hydraulic motor immediately goes
into emergency shutdown
518435 12 Yellow
N004: Control error (controller)
– Interim voltage temporarily exceeded
Error
1. Select the “Turtle” speed
range
2. Reducing engine speed