BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm 8-21
Malfunctions 8
Service brake (brake pressure switch)
Error code FMI
Warning
light
Error description Remedy
518958
3 Yellow
S009: Signal range exceeded or short circuit to
positive supply voltage
– Differential lock without function
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
26 Yellow
S009: Signal outside of the valid range
– Differential lock without function
27 Yellow
S009: Open circuit or short circuit to ground
– Differential lock without function