BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm 8-23
Malfunctions 8
Differential lock
Error code FMI
Warning
light
Error description Remedy
518972
3 Yellow
S025 – Push button (joystick):
Signal range exceeded or short circuit to positive
supply voltage
– Differential lock without function
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
27 Yellow
S025 – Push button (joystick):
Open circuit or short circuit to ground
–Differential lock without function
28 Yellow
S025 – Button (joystick):
Open control circuit or short circuit to positive
supply voltage.
– Differential lock without function
519357
5 Yellow
Y009 – Magnetic valve:
Power too low or open wiring
– Differential lock without function
6 Yellow
Y009 – Magnetic valve quickhitch lock:
Power too high or short circuit to vehicle ground
– Differential lock without function