8-24 BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
Operating motor
Error code FMI
Warning
light
Error description Remedy
518441 12
Red
N004: Control error (controller)
– Machine immediately goes into emergency
shutdown
Critical error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
518442
0 Yellow
N004 – Threshold exceeded by far
– Operating engine immediately goes into
emergency shutdown – Drive engine goes via
ramp into emergency shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
1 Yellow
N004 – Threshold exceeded by far
– Operating engine immediately goes into
emergency shutdown
– Drive engine goes via ramp into emergency
shutdown
12 Yellow
N004: Control error (controller)
– Temperature on the heat sinks is faulty
– Machine can continue to be operated with loss
of output. The output loss is
temperature-dependent and occurs
in three stages.
If the temperature is not lowered:
– Machine immediately goes into emergency
shutdown
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
Critical error
Have the error rectified by an
authorized service center.
16
N004 – Threshold exceeded
– Vehicle can still be operated in emergency
operation
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.

Table of Contents