EasyManua.ls Logo

Wacker Neuson KRAMER 5055e

Wacker Neuson KRAMER 5055e
420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm 8-31
Malfunctions 8
Load stabilizer
Error code FMI
Warning
light
Error description Remedy
518993
3Yellow
S044 – Button:
Signal range exceeded or short circuit to positive
supply voltage
– Load stabilizer without function
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
26 Yellow
S044 – Button:
Signal outside of the valid range
– Load stabilizer without function
27 Yellow
S044 – Button:
Open circuit or short circuit to ground
– Load stabilizer without function
519369
5Yellow
Y020 – Magnetic valve:
Power too low or open wiring
– Load stabilizer without function
– Work operation not possible
6Yellow
Y020 – Magnetic valve:
Power too high or short circuit to vehicle ground
– Load stabilizer without function
– Work operation not possible
519370
5Yellow
Y021 – Magnetic valve:
Power too low or open wiring
– Load stabilizer without function
– Work operation not possible
6Yellow
Y021 – Magnetic valve:
Power too high or short circuit to vehicle ground
– Load stabilizer without function
– Work operation not possible

Table of Contents