EasyManua.ls Logo

Wacker Neuson KRAMER 5055e

Wacker Neuson KRAMER 5055e
420 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-30 BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
Pressure relief of 3rd control circuit (button)
Error code FMI
Warning
light
Error description Remedy
519076
3 Yellow
S127: Signal range exceeded or short circuit to
positive supply voltage
– Pressure relief without function
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
26 Yellow
S127: Signal outside of the valid range
–Pressure relief without function
27 Yellow
S127: Open circuit or short circuit to ground
–Pressure relief without function

Table of Contents

Related product manuals