BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm 8-29
Malfunctions 8
3rd control circuit (continuation)
Error code FMI
Warning
light
Error description Remedy
518982
3 Yellow
S032 – Switch operation:
Signal range exceeded or short circuit to positive
supply voltage
– 3rd control circuit and quick unlocking without
function
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
26 Yellow
S032 – Switch operation:
Signal outside of the valid range
– 3rd control circuit and quick unlocking without
function
27 Yellow
S032 – Switch operation:
Open circuit or short circuit to ground
– 3rd control circuit and quick unlocking without
function
519365
5 Yellow
Y016 – Lock magnetic valve:
Power too low or open wiring
– 3rd control circuit without function
6 Yellow
Y016 – Locking magnetic valve:
Power too high or short circuit to vehicle ground
– 3rd control circuit without function
519366
5 Yellow
Y017 – Unlock magnetic valve:
Power too low or open wiring
– 3rd control circuit and quick release without
function
6 Yellow
Y017 – Unlocking magnetic valve:
Power too high or short circuit to vehicle ground
–3rd control circuit and quick release without
function