BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm 8-33
Malfunctions 8
7-pole front power outlet
Drive interlock
Error code FMI
Warning
light
Error description Remedy
518976 26 Yellow
S027 – Rocker switch:
Signal outside of the valid range
– Front power outlet without function
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
519016
3 Yellow
S067 – Button joystick:
Signal range exceeded or short circuit
to positive supply voltage
– Front power outlet without function
26 Yellow
S067 – Button joystick:
Signal outside of the valid range
– Front power outlet without function
27 Yellow
S067 – Button joystick:
Open circuit or short circuit to ground
– Front power outlet without function
519765 24 Yellow
K016 – Relays:
Logical error/software
– Front power outlet without function
Error code FMI
Warning
light
Error description Remedy
518080 9 Yellow
N021 –
CAN error: time-out or missing signal
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
518081
2–
N021 –
Antenna status: error
(open circuit or short circuit)
12 –
N021 –
Transponder status: No key recognized
Check if the right key was
used.
If necessary, code key.
13 –
N021 –
Transponder status: Code exists but not valid
Check if the right key was
used.