8-34 BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
Immobilizer (continuation)
Error code FMI
Warning
light
Error description Remedy
518082
26
N021 –
Relays 1 Status: short circuit
(voltage if relays contacts are open)
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
27
N021 –
Relays 1 Status: open circuit
(no voltage if relays contacts are closed)
518083
26
N021 –
Relays 2 Status: short circuit
(voltage if relays contacts are open)
27
N021 –
Relays 2 Status: open circuit
(no voltage if relays contacts are closed)
518084
26
N021 –
Relays 3 Status: short circuit
(voltage if relays contacts are open)
27
N021 –
Relays 3 Status: open circuit
(no voltage if relays contacts are closed)
518085 10
N021 –
CAN-Bus-Status: receiver error
518086
16
N021 –
Battery status: Overvoltage (29.8 V)
18
N021 –
Battery status: Undervoltage (7.7 V)
518087 13
N021 –
Immobilizer active
Check if the right key was
used.
518089 02
N021 –
Reservoir full
Reduce number of keys.