8-34 BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
Immobilizer (continuation)
Error code FMI
Warning
light
Error description Remedy
518082
26
N021 –
Relays 1 Status: short circuit
(voltage if relays contacts are open)
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
27
N021 –
Relays 1 Status: open circuit
(no voltage if relays contacts are closed)
518083
26
N021 –
Relays 2 Status: short circuit
(voltage if relays contacts are open)
27
N021 –
Relays 2 Status: open circuit
(no voltage if relays contacts are closed)
518084
26
N021 –
Relays 3 Status: short circuit
(voltage if relays contacts are open)
27
N021 –
Relays 3 Status: open circuit
(no voltage if relays contacts are closed)
518085 10
N021 –
CAN-Bus-Status: receiver error
518086
16
N021 –
Battery status: Overvoltage (29.8 V)
18
N021 –
Battery status: Undervoltage (7.7 V)
518087 13
N021 –
Immobilizer active
Check if the right key was
used.
518089 02
N021 –
Reservoir full
Reduce number of keys.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Wacker Neuson KRAMER 5055e and is the answer not in the manual?

Wacker Neuson KRAMER 5055e Specifications

General IconGeneral
BrandWacker Neuson
ModelKRAMER 5055e
CategoryFront End Loaders
LanguageEnglish

Related product manuals