W&T Mode UDP peer
Subject to error and alteration
13�1�1 Setting the local UDP port number
SETUP Port x
TCP/IP Mode
...
Port List
...
Local Port TCP/UDP
To send a UDP datagram to the Com-Server, the sender needs
the IP address of the Com-Server as well as its UDP port num-
ber on which the data are received. Access to the serial port
on the Com-Server per UDP takes place through the port spe-
cified in the above menu branch. The factory default setting
is 8000.
The Com must be prepared for receiving UDP datagrams by
specifying static destination parameters or by enabling serial
addressing in the menu path UDP Client.
The entire data range of received UDP packets is sent transpa-
rent to the serially connected device.