84
W&T Packetizing serial datagrams
10�1�2 Startsequence + Lengthfield
The Com-Server sends the datagram after reception of a Start
Sequence and evaluation of a length specification contained in
the datagram.
n
Activate this Packet Option (Telnet)
Activates the selected option for serial data reception.
n
Start Sequence Size
Enter the length of the Start Sequence in bytes. The max.
Length is 3.
n
Start Sequence
Hexadecimal, space-delimited byte sequence of the re-
spective Start Sequence. The input field is only activated if
the sequence size was previously specified and sent to the
Com-Server.
n
Length Field Offset
Start position of the length field within the serial datagram
in bytes. Counting method beginning with 0.
n
Size
Length of the length field in bytes. In the protocol field de-
fined by Length Field Offset, Size and Byte Order, the Com-
Server expects specification of the total length of the serial
datagram, including any Start Sequence and appended
checksum. If the length specification is defined differently
within the serial protocol, a corresponding correction may
be needed using the Additional Bytes option.
1
Clean network-side packetizing is only assured if
the serial datagrams do not exceed the MTU of the
Com-Server. The factory default setting for this is 560
bytes. In the menu path Setup System r Setup TCP/IP r
MTU this can be extended to 1024 bytes.